RU EN

IKV-1-3-1 vibration measuring channel cryogenic version

IKV-1-3-1 vibration measuring channel cryogenic version

The indicator is designed to measure vibration displacement span, rotational speed, axial shift and detecting marks in vibration monitoring systems of rotary machines at low temperatures;

It consists of a DS-1 eddy-current transducer and AV131-V converter (in the connecting box).

Output signal type – 4-20 mA, 0-10 V;

Related equipment

These vibration transducers are tuned to a specific temperature and a specific metal according to customer requirements.
The operating temperature range of the vibration transducer relative to the setting temperature is ± 30 ° C, within the range of -100 ... -200 ° C.

Example 1. To control the pump for pumping liquid nitrogen, the sensor is tuned to a temperature of -196 ° C and provides the claimed accuracy of the characteristics in the temperature range -166 to -200 ° C.

Example 2. To control the pump for transferring liquefied gas at a temperature of -154 ° C, the sensor is set to a temperature of -154 ° C and provides the claimed accuracy of the characteristics in the temperature range -124 to -184 ° C.

Not a means of measurement!

specifications

Measurement parameters

  • Range of measurement of vibration displacements, μm
    0-250 (eddy-current transducer DS-1)
  • Range of measurement of a gap, mm
    0.25-2.75 (eddy-current transducer DS-1)
  • Range of measurement of speed, rpm
    30-120000
  • Sampling frequency of the phase meter signal, kHz
    18.75
  • Measurement cycle time, μs
    26.6
  • Permissible deviation of rotation frequency,%
    1
  • Accuracy of gap measurement, μm
    ±50 (eddy-current transducer DS-1)
  • Permissible deviation of range,%
    5
  • Installation clearance (default), mm
    1.5±0.2 (eddy-current transducer DS-1)

Interface

  • Output signal type
    "current loop" 4-20 mA
    "by voltage" 0-10 V
  • Supply voltage range, V
    24 (12-30)

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0Ex ia IIC T6...T1 Ga X (eddy-current transducer DS-1)

Design parameters

  • Version
    IKV-1-3-1 ver. C (eddy-current transducer DS-1 ver.00,
    AV131-V converter, connecting box)
  • Overall dimensions, mm
    D(8.5) L(50; 70; 90) (eddy-current transducer DS-1 (M10x1))
    105x22.5x70 (AV131-V converter)
    277x217x84 (connecting box)
  • Weight, kg, not more than
    0.35 (eddy-current transducer DS-1)
    2.5 (connecting box)
  • Mounting type
    threaded hole M10x1 (eddy-current transducer DS-1)
  • Protection class
    IP65/IP68 (eddy-current transducer DS-1)
    IP66 (connecting box)

Operating parameters

  • Operating temperature range, ºС
    -100...-200 (eddy-current transducer)
    -40...+60 (AV131-V converter)

Reliability parameters and manufacturer's guarantees

  • MTBF, hours, not less than
    40 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    10
  • Installed device life, hours, not less than
    80 000
Service center