RU EN

IKV-1-4-4 vibration measuring channel

IKV-1-4-4 vibration measuring channel

Designed to measure axial displacement of industrial equipment units*;

Area of application - control of axial displacement of working mechanisms in power engineering and machine-building industry;

It consists of a DS-x eddy-current transducer and the AS 144 transducer (installed in the connection box).

Channel versions:

  • IKV-1-4-4 ver. A - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 144 converter, connection box**.

Output signal type - -1...-17 V;

*By default, the channel is set to 40X metal

**Available as an option

Related equipment

TIK-BIS
safety barriers

specifications

Metrological parameters

  • Conversion coefficient, V/mm / Range of measurement of the axial shift, mm
    8 (7.8; 6.4) / 0.25-2.25 (0.25-2.30; 0.25-2.75) (DS-0 eddy-current transducer)
    8 (7.8; 6.4) / 0.25-2.25 (0.25-2.30; 0.25-2.75) (DS-1 eddy-current transducer)
    4 (3.2) / 0.5-4.5 (0.5-5.5) (DS-2 eddy-current transducer)
    4 (2) / 5.5-9.5 (1.0-9.0) (DS-3 eddy-current transducer)
  • Installation gap (default), mm
    1.25±0.2 (1.275±0.2; 1.5±0.2) (DS-0 eddy-current transducer)
    1.25±0.2 (1.275±0.2; 1.5±0.2) (DS-1 eddy-current transducer)
    2.5±0.2 (3±0.2) (DS-2 eddy-current transducer)
    7.5±0.2 (5±0.2) (DS-3 eddy-current transducer)

Interface

  • Output signal type
    -1...-17 V
  • Supply voltage range, V
    -17.5...-26

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0Ex ia IIC T6...T1 Ga X (DS-x eddy-current transducer)
    0Ex ia IIC T6...T1 Ga X (AS 1xx converter)
    0Ex ia IIC T6...T4 Ga X (connection box)

Design parameters

  • Overall dimensions, mm
    D(6.8) L(50; 70; 90) (DS-0 eddy-current transducer)
    D(8.5) L(30; 50; 70; 90) (DS-1 eddy-current transducer)
    D(14.5) L(50; 70; 90) (DS-2 eddy-current transducer)
    D(22.5) L(90) (DS-3 eddy-current transducer)
    98.5x27.5x59 (AS 144 converter)
    277x254.5x83 (connection box)
  • Weight, kg, not more than
    0.25 (DS-0, DS-1 ver. 00, 01 eddy-current transducer)
    0.3 (DS-2 ver. 00, 01 eddy-current transducer)
    0.4 (DS-3 ver. 00, 01 eddy-current transducer)
    0.1 (AS 144 converter)
    2.5 (connection box)
  • Mounting type
    M8x1 threaded hole (DS-0 eddy-current transducer)
    M10x1 threaded hole (DS-1 eddy-current transducer)
    M16x1 threaded hole (DS-2 eddy-current transducer)
    M24x1 threaded hole (DS-3 eddy-current transducer)
  • Protection class
    IP65/IP68 (DS-x eddy-current transducer)
    IP20 (AS 144 converter)
    IP65/IP67 (connection box)

Operating parameters

  • Operating temperature range, ºС
    -40...+135 (DS-x ver. 00, 01 eddy-current transducer)
    -60...+135 (DS-x ver. 00, 01 eddy-current transducer, climatic version HL)
    -40...+70 (AS converter)
    -60...+70 (AS converter, climatic version HL)

Reliability parameters and manufacturer's guarantees

  • MTBF, hours, not less than
    40 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    10
  • Installed device life, hours, not less than
    80 000
  • Time between verifications
    1 year
Service center