RU EN
Certificate ISO 9001

DVA sensor for emergency protection of the pumping unit

DVA sensor for emergency protection of the pumping unit

Designed for automatic monitoring of the state of the drive of a sucker rod oil pump of the "machine-rocking" type and its protection against destruction in the event of an emergency.

  • simultaneous measurement of instantaneous and average vibration parameters in various representations (vibration acceleration, vibration velocity, vibration displacement) along two coordinate axes, two tilt angles and temperature (at the sensor installation site);
  • processing / analysis of information, assessment of the levels of measured parameters, control of a discrete output, thanks to the controller integrated in the sensor;
  • the presence of a digital communication interface for transmitting information to the upper level, as well as for changing your own settings (response delay time, setting level);
  • can be installed on the pimping unit of all types, both domestic and imported.

Additional photos

specifications

Metrological parameters

  • Operating frequency range, Hz
    2-1000
    5-1000
    10-1000
  • Range of measurement of vibration velocity, mm/s
    0-100
  • Range of measurement of vibration acceleration, m/s2
    0-100
  • Range of measurement of vibration displacement, μm
    0-2000
  • Angles accuracy
    ±20

Interface

  • Output signal type
    digital RS-485
    discrete output
  • Protocol
    Modbus RTU
  • Supply
    10-24V (for devices marked Ex ia)
    10-36V (for devices without marking the level of explosion protection)
  • Power consumption, W, not more
    1
  • Speed of the interface RS-485
    up to 1 Mbit/s

Explosion protection

  • Marking
    0Ex ia IIC T5...T6 Ga X

Design parameters

  • Version
    5-pin connector on the housing
  • Overall dimensions, mm
    32x70x26
  • Weight, kg, not more than
    0.25
  • Mounting type
    screw M6 1 pc.
  • Protection class
    IP65/IP68

Operating parameters

  • Operating temperature range, ºС
    -40...+80 (climatic version H, for 0Ex ia IIC T5...T6 Ga X)
    -60...+80 (climatic version X, for 0Ex ia IIC T5...T6 Ga X)

Reliability parameters and manufacturer's guarantees

  • Mean time between failures, hours, not less than
    40 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    10
  • Time between verifications
    2 years