RU EN

IKV-1-2-1 type V vibration measuring channel

IKV-1-2-1 type V vibration measuring channel

Designed for measurement of the root-mean square (RMS) value of vibration velocity;

Consists of DV-1 type 07 (08) vibration transducer, AV 121 charge amplifier and a TIK-BIS.1X1 safety barrier installed in the connecting box (the box and the barrier are delivered at the request of the Customer);

Output signal type – 4-20 mA








Additional photos

Reviews

Related equipment

TIK-BIS
safety barriers

specifications

Metrological parameters

  • Conversion coefficient, mA*s/mm / Range of indications of RMS vibration velocity, mm/s
    0.8 / 0-20
    0.533 / 0-30
    0.32 / 0-50
  • Operating frequency range, Hz
    2-1000
    10-1000
  • Electrical resistance of insulation between the vibration converter circuit and the shell, MOhm, not less than
    40

Interface

  • Output signal type
    "current loop" 4-20 mA
  • Supply voltage range, V
    10-24

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0Ex ia IIC T6...T1 Ga X (DV-1 vibration transducer)
    not lower than 0Ex ia (AV 121 charge amplifier)
  • Connection
    through TIK-BIS safety barrier

Design parameters

  • Version
    IKV-1-2-1 type V (DV-1 type 07 vibration transducer or
    DV-1 type 08 vibration transducer, AV 121 charge amplifier,
    optional - TIK-BIS.1X1.0X0X safety barrier, connecting box)
  • Overall dimensions, mm
    Ø39.25x39.5 (DV-1 vibration transducer)
    105x22.5x59 (AV 121 charge amplifier)
  • Weight, kg, not more than
    0.3 (DV-1 vibration transducer)
    0.1 (AV 121 charge amplifier)
  • Mounting type
    screw M4x21 (M4x28) 3 PCs.
  • Protection class
    IP65/IP68 (DV-1 type 07 vibration transducer)
    IP65 (DV-1 type 08 vibration transducer)
    IP20 (AV 121 charge amplifier)

Operating parameters

  • Operating temperature range, ºС
    -40...+85 (DV-1 vibration transducer, AV 121 charge amplifier,
    climatic version H)
    -60...+85 (DV-1 vibration transducer, AV 121 charge amplifier,
    climatic version X)

Reliability parameters and manufacturer's guarantees

  • MTBF, hours, not less than
    40 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    10
  • Installed device life, hours, not less than
    80 000
  • Time between verifications
    1 year
Service center