Channel vibration measuring IKV-1-3-1

Channel vibration measuring IKV-1-3-1

Designed to measure the vibration displacement span in diagnostic and emergency protection systems (EPS)*;

It consists of a DS-1 eddy-current transducer (DS-2, DS-3) and AS131 converter (in the measuring unit), or AS1312 converter on the connecting cable.

Application on the compressor equipment is possible;

Type of output signal - 4...20 mA;

*By default, the channel is set to 40X metal




Additional photos

Reviews

specifications

Metrological parameters

  • Measurement range of the amplitude of vibration displacement, um
    0...125, 0...250 (eddy-current transducer DS-1 (M8x1))
    0...100, 0...250 (eddy-current transducer DS-1 (M10x1))
    0...500, 0...1 000 (eddy-current transducer DS-2)
    0...2 000 (eddy-current transducer DS-3)
  • Operating frequency range, Hz
    2...500
  • Installation gap (default), mm
    1,0±0,2 (eddy-current transducer DS-1 (M8x1))
    1,5±0,2 (eddy-current transducer DS-1 (M10x1))
    3±0,2 (eddy-current transducer DS-2)
    5±0,2 (eddy-current transducer DS-3)
  • Electrical resistance of insulation between the vibration converter circuit and the shell, MOhm, not less than
    40

Interface

  • Output signal type
    "current loop" 4...20 mA
  • Supply voltage range, V
    10...24

Explosion protection

  • Kind
    safe electrical circuit
  • Marking
    0ExiaIICT6 (eddy-current transducer DS-1, DS-2, DS-3)
    0ExiaIICT5 (measuring unit)
  • Connection
    via TIK-PLC 112 controller
    via safety barrier

Design parameters

  • Version
    IKV-1-3-1 ver. A (eddy-current transducer
    DS-1 (DS-2, DS-3) ver.00 or 01 (with connector),
    AS131 converter, measuring unit, safety barrier
    TIK-BIS-52-7 (TIK-BIS-51-7, TIK-BIS-12-1))


    IKV-1-3-1 ver. B (eddy-current transducer
    DS-1 (DS-2, DS-3) ver.02 with connector and converter
    AS1312 on the cable), measuring unit, safety
    barrier TIK-BIS-52-7 (TIK-BIS-51-7, TIK-BIS-12-1))

  • Overall dimensions, mm
    D(6,8) L(50; 70; 90) (eddy-current transducer DS-1 (M8x1))
    D(8,5) L(50; 70; 90) (eddy-current transducer DS-1 (M10x1))
    D (14,5) L(50; 70; 90) (eddy-current transducer DS-2)
    D (22,5) L(90) (eddy-current transducer DS-3)
    98,5х27,5х59 (AS131 converter)
    277х217х84 (measuring unit)
  • Weight, kg, not more than
    0,35 (eddy-current transducer DS-1)
    0,4 (eddy-current transducer DS-2)
    0,5 (eddy-current transducer DS-3)
    0,1 (AS131/AS1312 converter)
    2,5 (measuring unit)
  • Mounting type
    threaded hole M8x1 (eddy-current transducer DS-1)
    threaded hole M10x1 (eddy-current transducer DS-1)
    threaded hole M16x1 (eddy-current transducer DS-2)
    threaded hole M24x1 (eddy-current transducer DS-3)
  • Protection class
    IP 67 (eddy-current transducer DS-1, DS-2, DS-3)
    IP 20 (AS131 converter)
    IP 66 (measuring unit)

Operating parameters

  • Operating temperature range, ºС
    -40...+135 (eddy-current transducer)
    -60...+135 (eddy-current transducer, climatic version HL)
    -40...+70 (AS converter)
    -60...+70 (AS converter, climatic version HL)

Reliability parameters and manufacturer's guarantees

  • Mean time between failures, hours, not less than
    10 000
  • Warranty service life, months
    18
  • Service life, years, not less than
    10