RU EN
Certificate ISO 9001

IKV-1-4-1 vibration measuring channel

IKV-1-4-1 vibration measuring channel

Designed to measure the axial shift in the emergency protection system (EPS)*;

Consists of DS-1 (DS-2, DS-3) eddy-current transducer, AS141 converter (in the connecting box) or AS1412 converter on the connecting cable. If it is necessary to display the measured parameters, additional display units are supplied;

Type of output signal - 4...20 mA;

*By default, the channel is set to 40X metal





Related equipment

TIK-PLC 112
controller
TIK-BIS
safety barriers

Additional photos

Reviews

specifications

Metrological parameters

  • Range of measurement of the axial shift, mm
    0.25-2.25 (eddy-current transducer DS-1 (M8x1))
    0.25-2.75 (eddy-current transducer DS-1 (M10x1))
    0.5-5.5 (eddy-current transducer DS-2)
    5.5-9.5 (1.0-9.0) (eddy-current transducer DS-3)
  • Measurement cycle time, s
    1.0* (0.0005)**
    *factory mode
    **set by jumper
  • Installation gap (default), mm
    1.25±0.2 (eddy-current transducer DS-1 (M8x1))
    1.5±0.2 (eddy-current transducer DS-1 (M10x1))
    3.0±0.2 (eddy-current transducer DS-2)
    5.5(5)±0.2 (eddy-current transducer DS-3)

Interface

  • Output signal type
    "current loop" 4...20 mA
  • Supply voltage range, V
    10...24

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0ExiаIICT6 (eddy-current transducer DS-1, DS-2, DS-3)
    0ExiаIICT5 (connecting box)
  • Connection
    through TIK-PLC 112 controller
    through TIK-BIS safety barrier

Design parameters

  • Version
    IKV-1-4-1 ver. A (eddy-current transducer
    DS-1 (DS-2, DS-3) ver.00 or 01 (with connector), AS141
    converter, connecting box, TIK-BIS safety barrier)


    IKV-1-4-1 ver. B (eddy-current transducer
    DS-1 (DS-2, DS-3) ver.02 with connector and AS1412
    converter on the cable), connecting box, TIK-BIS safety barrier)


    IKV-1-4-1 ver. V (eddy-current transducer
    DS-1 (DS-2, DS-3) ver.02 with connector and AS1412 converter
    on the cable), display unit, connecting box, TIK-BIS safety barrier)
  • Overall dimensions, mm
    D(6.8) L(50; 70; 90) (eddy-current transducer DS-1)
    D(8.5) L(50; 70; 90) (eddy-current transducer DS-1)
    D (14.5) L(50; 70; 90) (eddy-current transducer DS-2)
    D (22.5) L(90) (eddy-current transducer DS-3)
    98.5x27.5x59 (AS141 converter)
    105x22.5x67 (display unit)
    277x217x84 (connecting box, for ver. A, B)
    300x108x195 (connecting box, for ver. V)
  • Weight, kg, not more than
    0.35 (eddy-current transducer DS-1)
    0.4 (eddy-current transducer DS-2)
    0.5 (eddy-current transducer DS-3)
    0.1 (AS141/AS1412 converter)
    0.1 (display unit)
    2.5 (connecting box, for ver. A, B)
    3.25 (connecting box, for ver. V)
  • Mounting type
    threaded hole M8x1 (eddy-current transducer DS-1)
    threaded hole M10x1 (eddy-current transducer DS-1)
    threaded hole M16x1 (eddy-current transducer DS-2)
    threaded hole M24x1 (eddy-current transducer DS-3)
  • Protection class
    IP67 (eddy-current transducer DS-1, DS-2, DS-3)
    IP20 (AS141 converter)
    IP20 (display unit)
    IP66 (connecting box)

Operating parameters

  • Operating temperature range, ºС
    -40...+135 (eddy-current transducer)
    -60...+135 (eddy-current transducer, climatic version HL)
    -40...+70 (AS converter)
    -60...+70 (AS converter, climatic version HL)

Reliability parameters and manufacturer's guarantees

  • Mean time between failures, hours, not less than
    10 000
  • Warranty service life, months
    18
  • Service life, years, not less than
    10
Service center